Your shopping cart is empty!
Equipment:
UTS– smoke tube boilers, where water circulates between the steel walls of the furnace and the pipes. The outer surface is insulated with a layer of mineral wool. The quantity of air is automatically controlled by thermostatic draft regulator. Boilers are designed for the heating of industrial, domestic, administrative and other rooms, where the central heating system is installed. Water circulation in a boiler and the system is forced.The boilers have been awarded certificates by European Union. They fire solid fuel: wood, chips, sawdust briquettes, pellets, coal, etc.
Boiler can be equipped with automatic biomass burners:
TECHNICAL PROFILE
Thermal capacity, KW ± 7%: - when burning coal (calorific value of at least 29,880 MJ/kg) - when burning firewood of maximum 20% humidity |
70 64 |
Efficiency rate, % | 74…82 |
Temperature of boiler water, °C - return, at least - effluent, maximum |
65 95 |
Boiler water pressure, maximum, MPa | 0,4 |
Boiler water circulation | forced |
Boiler water capacity, l | 185 |
Boiler heating surface, m² | 5,3 |
Pressure outside boiler, Pa | 25 |
Temperature of combustion gas, °C | 250 |
Type of fuel | Lump solid, with add-on combustion chamber: bulky wood waste (sawdust, chips) |
Coal (calorific value is not less than 29,88 MJ/kg) - thickness of layer, mm - use kg/val. |
50-200 10,4 |
Dry up to 20% of humidity, and not more Ø130 chopped wood - height of charge, mm - use, kg/val. |
200-350 13,6 |
Reference heated floor space (building thermal resistance is not less than 2,5 m²/kW) |
560-770 |
Overall dimentions, mm - length - height - width |
1430 1600 590 |
Furnace depth / max. firewood length, mm | 700/550 |
Boiler service life, years | 10 |
Boiler weight, kg - empty - full |
685 957 |
Electrical profile(models with air supply) - voltage and frequency, V/Hz - use of power, kW |
230/50 0,26 |