SIGA CSHHFT-340 (8)

SIGA CSHHFT-340 (8)

Product Code: SIGA CSHHFT-340 (8)
Availability:
Pre-Order
Description

Description:

The range includes models that cover a refrigeration capacity ranging from 1 to 1500 kW. Compact chillers are for outdoor installation. The range has been designed for use both in the process and comfort sectors. The machines are equipped with all the components that ensure automatic cooling of water or a water/glycol solution. To guarantee maximum operating safety the units have (or can have) two completely independent refrigeration circuits. All units are supplied with a full oil and refrigerant load after having been factory tested. The chillers are divided in two product ranges: chillers with scroll compressors and chillers with screw compressors. For scrolls refrigerants used are R407C/R410A/R404A, while for screw compressors refrigerants are R407C/R134a/R404A. Models where scroll compressors are used are installed with shell and tube evaporators or plates evaporators (or coaxials). Models with screw compressors are installed with shell and tube evaporators, with optional opportunity of high efficiency evaporators for R134a refrigerant, which reach energetic Class A.

Options:

1.0 MECHANICAL CONFIGURATION     3.0 REFRIGERANT CIRCUIT CONFIGURATION (drawing code n. )      
LNJ Low noise version (RV included)   HPG High pressure gauge      
GPC Condenser coil protection   LPG Low pressure gauge      
ATS Spring type antivibrant mounting   LT Low ambient temperature until -30°C (RV, RC,  EB included)      
CV Epoxy coated condenser coil   LW Low water temperature until -10°C outlet (RC,  RV, thicker insulation included)    
CF Condenser filter   PDS Desuperheater    
CG Condenser treatment (blygold)   4.0 ELECTRIC CIRCUIT CONFIGURATION          
2.0 HYDRIC CIRCUIT CONFIGURATION (drawing code n. )     OFC On-off compressors signal    
T Tank carbon steelv included safety valve, air vent nipple (closed type)   OFR Remote control (on/off)  
WP P3 Pump   OFRC Remote control display with on/off remote+alarm management, Carel microchiller2 (IP54)
DP Double P3 pump (valve betwwen tank and pump included)   RS485 Serial card for modbus RS485  
PH P5 Pump   RV Electronic fan speed control
DPH Double P5 pump (valve betwwen tank and pump included)   RVG Volt-metric relay (CSF included)
BPA Automatic by pass until 50% of the flow rate   RC Cranckase heater
XV Expansion vessel kit available for closed-type tank   SF Soft start
RAGE Evaporator antifreeze heater   IRC Compressor inverter
RAGT Antifreeze heater inertial tank   EC EC fans        
FL Flow switch installed                      
LLA Electronic low level alarm        
VTP Valve between tank and pump                      

 

Technical Specification: 

Cooling and Heating CSHHFT Heat Pump

 

Model

230 (8)

280 (8)

340 (8)     

370 (8)

     

 

 

 

 

NOMINAL COOLING CAPACITY (1)                                         

 

kW

227,00

277,00

319,00

365,00

TOTAL COMPRESSORS NOMINAL ABSORBED POWER (1)

 

kW

66,80

85,20

97,80

108,00

EER (1)                                                                             

 

kW/kW

2,97

2,92

2,97

3,05

ESEER (1)                                                                         

   

4,00

4,10

4,10

4,00

IPLV (1)                                                                             

   

4,60

4,70

4,80

4,60

Heating mode

   

 

 

 

 

NOMINAL HEATING CAPACITY (2)                               

 

kW

232,00

285,00

322,00

369,00

TOTAL COMPRESSORS NOMINAL ABSORBED POW (2)

 

kW

63,10

80,50

90,50

99,90

COP (2)                                                                             

 

kW/kW

3,18

3,16

3,22

3,31

HYDRAULIC SECTION

   

 

 

 

 

NOMINAL WATER FLOW                                               

 

m3/h

39,80

49,10

55,40

63,40

EVAPORATOR PRESSURE DROP                                

 

kPa

58,00

60,00

49,00

56,00

AVAILABLE PRESSURE (3)

P3

mca

26,20

25,10

24,90

23,80

MAXIMUM PUMP ABSORBED POWER (3)

 

kW

8,30

8,30

8,30

10,20

MAXIMUM PUMP ABSORBED CURRENT (3)

 

A

14,10

14,10

14,10

17,40

AVAILABLE PRESSURE (4)

P5

mca

48,20

47,50

47,80

45,80

MAXIMUM PUMP ABSORBED POWER (4)

 

kW

16,22

16,22

16,22

16,22

MAXIMUM PUMP ABSORBED CURRENT (4)

 

A

26,60

26,60

26,60

26,60

HYDRAULIC CONNECTIONS                                         

 

BSP/DN

DN125

DN125

DN125

DN150

TANK VOLUME (5)

 

dm3

500,00

500,00

500,00

500,00

COMPRESSORS                   

 

nr.

4,00

4,00

4,00

4,00

REFRIGERATING CIRCUITS

 

nr.

2,00

2,00

2,00

2,00

PARTITION STEP                  

 

nr.

1,00

1,00

1,00

1,00

REFRIGERANT                      

   

R410A

R410A

R410A

R410A

FAN SECTION (AXIAL)

   

 

 

 

 

TOTAL AIR FLOW                 

 

m3/h

91000,00

90000,00

85000,00

102000,00

FANS                                           

 

nr.

5,00

5,00

5,00

6,00

FANS ABSORBED POWER      

 

kW

9,70

9,70

9,70

11,64

FANS ABSORBED CURRENT  

 

A

19,50

19,50

19,50

23,40

TOTAL ELECTRIC DATA          

 

IP

IP54

IP54

IP54

IP54

NOMINAL ABSORBED POWER (6)                           

 

kW

76,50

94,90

107,50

119,60

MAXIMUM ABSORBED CURRENT(F.L.A.) (6)          

 

A

165,30

197,90

227,30

260,60

MAXIMUM PEAK CURRENT  (L.R.A.) (6)                  

 

A

353,80

425,30

478,00

511,30

ELECTRIC FEED                              

 

V/Ph/Hz

400/3/50

400/3/50

400/3/50

400/3/50

NOISE DATA

   

 

 

 

 

SOUND PRESSURE (6) (7)              

 

dB(A)

64,10

65,50

65,50

65,90

DIMENSIONS AND WEIGHT

   

 

 

 

 

LENGTH                                            

 

mm

5350,00

5350,00

5350,00

6350,00

WIDTH                                               

 

mm

1105,00

1105,00

1105,00

1105,00

HEIGHT                                             

 

mm

2180,00

2180,00

2180,00

2180,00

 
 
Data referred to:
 
(1) Inlet/Outlet water temperature = +12/+7 °C - Condenser air temperature = +35°C; fouling factor = 0.000043 m²K/W                                           
(2) Inlet/Outlet water temperature = +40/+45 °C - Condenser air temperature = +7°C; fouling factor = 0.000043 m²K/W                                             
(3) With option WP (P3 pump) or DP (double P3 pump)                                                                                                                                             
(4) With option PH (P5 pump) or DPH (double P5 pump)                    
(5) With option T (Tank included safety valve, air vent nipple - closed configuration as per standard)          
(6) Data referred to standard configuration NT.NP (no tank - no pump)                
(7) Sound pressure level referred to measures according to normative ISO3744, pressure level at distance of 10 m, referred to free field on reflecting surface
(8) RV "fan speed cut-phase regulator" included                    
                     
SIGA GROUP UAB © 2024