Equipment:
USED. These recuperators, constituted of 10 series vertical construction and 10 series horizontal construction , are used to regenerate heat in public rooms, like pub, meeting room, small and medium locals.
WORKING PRINCIPLES. Inside hot air and outside cool air cross together but they don’t mix and mean while the hot of the inside defected air is being transferd to outside cool air. The efficiency of the recuperator in standard conditions (outside -5°C, inside 20°C with 50% of relative humidity) is always upper than 50%. The circular connections with exhaust and supply ducts can be fixed on each different side of the recuperator, to make easier the installation, for the RCAS series.
FEATURES. Painted and galvanized sheet steel case. Condense discharge drop tank. Acoustic insultation fire-retardant lining on the lower cover panel. Pleated filters. Efficiency F6-F7-F8-F9 as needed or requested. Backward blades impeller centrifugal fans with outside rotor (type RCAS 300-550-800-1000-1400) singlephase. Forward blades, singlephase, centrifugal fan, directly coupled (type RCAS 2600-4200),(type RCAS 5500- 6500-7000) threephase.
ACCESSORIES.
Electronic digital speed controller singlephase with 5 speed positions.
- Electric heater
- Water heater
- Other accessories
- Electric control for CO2 filters
TECHNICAL GRAPHICS:
|
TECHNICAL CHARACTERISTICS:
|
|
RCAS 300 |
RCAS 550 |
RCAS 800 |
RCAS 1400 |
RCAS 2600 |
Power Options |
B / F / Hz |
230 / -1/50 |
230 / -1/50 |
230 / -1/50 |
230 / -1/50 |
230 / -1/50 |
Power consumption of the motor |
kW |
2x0,08 |
2x0,09 |
2x0,12 |
2x0,23 |
2x0,37 |
Operating current |
A |
2x0,37 |
2x0,38 |
2x0,51 |
2x1,05 |
2x3,2 |
The effectiveness of the heat exchanger winter (5C + 20C) / summer (34C + 26C) |
% |
67/63 |
61/56 |
60/54 |
60/54 |
61/52 |
Noise max / min |
dB |
50/47 |
53/49 |
53/49 |
53/49 |
55/51 |
Connection to the duct |
mm |
150 |
150 |
150 |
250 |
315 |
Dimensions horizontal H / W / D |
mm |
275/600/600 |
275/700/700 |
275/700/700 |
375/900/900 |
425/1200/1200 |
Weight |
kg |
28 |
32 |
34 |
65 |
130 |
|
|
RCAS 3000 |
RCAS 4200 |
RCAS 5500 |
RCAS 6500 |
RCAS 7000 |
Power Options |
B / F / Hz |
230 / -1/50 |
230 / -1/50 |
380 / -3/50 |
380 / -3/50 |
380 / -3/50 |
Power consumption of the motor |
kW |
2x0,55 |
2x0,6 |
2x0,55 |
2x1,1 |
2x1,5 |
Operating current |
A |
2x4,2 |
2x6,6 |
2x2,5 |
2x3,6 |
2x5 |
The effectiveness of the heat exchanger winter (5C + 20C) / summer (34C + 26C) |
% |
60/52 |
54/48 |
52/47 |
54/48 |
54/48 |
Noise max / min |
dB |
56/52 |
58/54 |
58/54 |
67/63 |
71/69 |
Connection to the duct |
mm |
315 |
348 |
348 |
450 |
450 |
Dimensions horizontal H / W / D |
mm |
450/1200/1200 |
550/1350/1350 |
550/1350/1350 |
725/1350/1350 |
725/1350 / 1350 |
Weight |
kg |
140 |
165 |
165 |
193 |
193 |
SIZE:
|